Olympus Thunderbeat 5 mm, 10 cm, Inline Grip
Olympus Corporation of the Americas
Firm is initiating a removal due to continued reports of adverse events.
π₯ Medical Devices β’ 15,809 recalls
Olympus Corporation of the Americas
Firm is initiating a removal due to continued reports of adverse events.
A systematic positive bias of up to 20% was identified across the reportable potassium range, resulting in false elevation results of patient samples when using Medica s capillary tubes.
Medline has identified issues related to calibration of the equipment used to sterilize and package the devices. All products were exposed to the validated sterilization and packaging cycles; however, the identified calibration issues have the potential to impact the sterility assurance level (SAL) of the Recalled Products.
Due to an error when defining a new stereotactic reference that users fail to first change an already defined obsolete reference to a pre-plan reference. This may result in a treatment plan that potentially irradiates the incorrect patient location if the error is not detected by users.
Medline Industries
Medline Industries, LP is issuing a recall for specific items and lots of Medline Kits containing BD ChloraPrep Triple Swabsticks which BD determined may exhibit an open seal on the packaging of the applicators.
Philips North America
As part of the CT systems sub assembly, thirty-two (32) fasteners are used to attach the rotor to the bearing within the gantry. One or more of these fasteners may not be torqued to specification. If multiple fasteners are not torqued to specification, the rotor or rotor parts may become unsecured or displaced. While there has been no reported or observed event of expelled parts during gantry rotation, unsecured rotor parts may potentially be expelled.
Philips North America
As part of the CT systems sub assembly, thirty-two (32) fasteners are used to attach the rotor to the bearing within the gantry. One or more of these fasteners may not be torqued to specification. If multiple fasteners are not torqued to specification, the rotor or rotor parts may become unsecured or displaced. While there has been no reported or observed event of expelled parts during gantry rotation, unsecured rotor parts may potentially be expelled.
PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
Under certain conditions, the table may move unexpectedly when the Reset Geometry button is pressed - even when a table lock is active.
PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
Under certain conditions, the table may move unexpectedly when the Reset Geometry button is pressed - even when a table lock is active.
PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
Under certain conditions, the table may move unexpectedly when the Reset Geometry button is pressed - even when a table lock is active.
units manufactured in a limited time period may emit electromagnetic noise beyond the acceptable limits for RTCA application specified in RTCA DO-160G Chapter 21, Equipment Category M.
Intuitive Surgical
Robotic-assisted surgical system has Viewer Display manufactured with outdated firmware, may result in loss of one display-loss of 3D surgical field (depth perception) but 2D maintained, or loss of both displays-complete visualization loss, without fault, instruments remain active, could lead to instrument contact with tissue, resulting in injury/bleeding; may require alternate surgical modality.
Medline Industries
Medline Industries, LP is issuing a recall for specific items and lots of Medline Kits containing BD ChloraPrep Triple Swabsticks which BD determined may exhibit an open seal on the packaging of the applicators.
PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
Under certain conditions, the table may move unexpectedly when the Reset Geometry button is pressed - even when a table lock is active.
AVID Medical
Tyvek bag seal issue which may compromise sterility of the kit.
PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
Under certain conditions, the table may move unexpectedly when the Reset Geometry button is pressed - even when a table lock is active.
Philips North America
As part of the CT systems sub assembly, thirty-two (32) fasteners are used to attach the rotor to the bearing within the gantry. One or more of these fasteners may not be torqued to specification. If multiple fasteners are not torqued to specification, the rotor or rotor parts may become unsecured or displaced. While there has been no reported or observed event of expelled parts during gantry rotation, unsecured rotor parts may potentially be expelled.
The mix up of the impression caps provided in the package. The provided impression caps are magenta instead of brown.
PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
Under certain conditions, the table may move unexpectedly when the Reset Geometry button is pressed - even when a table lock is active.
There may be voids located in the seal of Tyvek pouches associated with identified catalog numbers and lots. A compromised sterile barrier has potential of bioburden contamination which could lead to infection.