TRIATHLON FEMORAL DISTAL AUGMENT 10MM - SIZE 2 RIGHT Catalog # 5541-A-202 - Product Usage: Triathlon Femoral Distal Augments are used with Triathlon TS Femoral Components during revision Total Knee Arthroplasty (TKA) and with Triathlon Primary PS Femoral Components during TKA to address distal femoral defects. (See attached IFU (IFU_Triathlon Total Knee_QIN 4376 Rev AB).
Class I - DangerousWhat Should You Do?
- Check if you have this product: All lots with an expiration date on or before 31 June 2024. Lot# A3E7R A3H9I A7A9A A9U7R AB37T AB74U ABB7S AE49B AES9B AGAR AGAS AGB3E AGT4E AGV3G AH37L AIO4V AO74U AOD9I ARO9B ASV7B ATA9R ATY3T AU99O AUX7R AY33Z AYO4V BAA4S BAB7Y BAH3D BAI7D BBE4R BBL4Y BDZ9H BER7H BH97L BLY9D BO77U BRR9H BRT7Z BSI4X BTD9B DGFR DGPY DNUW DOFW DRFR DRPA DYEK DYRN EDHL FNYJ FOGV FVVR FYST FYTP GFPG GJMG GJNM GYOD GYVG GZNA GZRT GZWG GZWS HHXY HHZF HHZZ HIBF HUPS HVBW HYHG HYJB IBTS IBTW IEVY ILAX ILBL INJO INNB INNE IUWT IVAB IYLR JBYI JFGV JFNZ JHDR JIKH JILH JNIX JVEZ JZSI KFYW KHHJ KHNX KHSO KMEX KSPV KVRZ KVVS KWPV KYND KZYB MEDM MFZX MGLY MLBP MMFV NEBU S3HS SOBP SPO4 SR4E TGGA TIYY TPPH TPTI UHIP USLI UT3I UZDD V4AH VA3Y VBGT VGGG VJHG VJYO VPBW VPYA VT43 VUWT VVJG VW3E WGRG WO4G WOYL WPJT WRXC WRYC WSDE WVWI WVWJ WXAV WXAW XAVX XAVY XDYL XDYM XGDX XGDY XIJC XKSY XKSZ XOCL XOCM XTJY XTJZ XVIO XVIP XWVK XWVM XYGP XYGR YBCC YBCD YESI YFJX YFJY YG3H YGSJ YGSK
- Do not eat it: Even if it looks and smells fine, do not consume this product.
- Throw it away or return it: You can return the product to the store for a full refund.
- Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
- Report problems: Report any issues to the FDA's Safety Reporting Portal.
⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.
Recall Details
- Company:
- Howmedica Osteonics Corp.
- Reason for Recall:
- Due to device overhang issue that protrudes beyond the medial periphery of the mating femoral component
- Classification:
- Class I - Dangerous
Dangerous or defective products that predictably could cause serious health problems or death.
- Status:
- terminated
Product Information
Full Description:
TRIATHLON FEMORAL DISTAL AUGMENT 10MM - SIZE 2 RIGHT Catalog # 5541-A-202 - Product Usage: Triathlon Femoral Distal Augments are used with Triathlon TS Femoral Components during revision Total Knee Arthroplasty (TKA) and with Triathlon Primary PS Femoral Components during TKA to address distal femoral defects. (See attached IFU (IFU_Triathlon Total Knee_QIN 4376 Rev AB).
Product Codes/Lot Numbers:
All lots with an expiration date on or before 31 June 2024. Lot# A3E7R A3H9I A7A9A A9U7R AB37T AB74U ABB7S AE49B AES9B AGAR AGAS AGB3E AGT4E AGV3G AH37L AIO4V AO74U AOD9I ARO9B ASV7B ATA9R ATY3T AU99O AUX7R AY33Z AYO4V BAA4S BAB7Y BAH3D BAI7D BBE4R BBL4Y BDZ9H BER7H BH97L BLY9D BO77U BRR9H BRT7Z BSI4X BTD9B DGFR DGPY DNUW DOFW DRFR DRPA DYEK DYRN EDHL FNYJ FOGV FVVR FYST FYTP GFPG GJMG GJNM GYOD GYVG GZNA GZRT GZWG GZWS HHXY HHZF HHZZ HIBF HUPS HVBW HYHG HYJB IBTS IBTW IEVY ILAX ILBL INJO INNB INNE IUWT IVAB IYLR JBYI JFGV JFNZ JHDR JIKH JILH JNIX JVEZ JZSI KFYW KHHJ KHNX KHSO KMEX KSPV KVRZ KVVS KWPV KYND KZYB MEDM MFZX MGLY MLBP MMFV NEBU S3HS SOBP SPO4 SR4E TGGA TIYY TPPH TPTI UHIP USLI UT3I UZDD V4AH VA3Y VBGT VGGG VJHG VJYO VPBW VPYA VT43 VUWT VVJG VW3E WGRG WO4G WOYL WPJT WRXC WRYC WSDE WVWI WVWJ WXAV WXAW XAVX XAVY XDYL XDYM XGDX XGDY XIJC XKSY XKSZ XOCL XOCM XTJY XTJZ XVIO XVIP XWVK XWVM XYGP XYGR YBCC YBCD YESI YFJX YFJY YG3H YGSJ YGSK
Official Source
Always verify recall information with the official FDA source:
View on FDA.govFDA Recall Number: Z-2758-2019
Related Recalls
TRI TS BASEPLATE SIZE 3. Part Number: 5521-B-300.
Howmedica Osteonics
Stryker has identified that Triathlon Universal Baseplate Size 3 (lot UZD9IB), is contained in packaging labeled as Triathlon Universal Baseplate Size 4 (lot TYX7OB), and Triathlon Universal Baseplate Size 4 (lot TYX7OB), is contained in packaging labeled as Triathlon Universal Baseplate Size 3, (lot UZD9IB).
TRI TS BASEPLATE SIZE 4. Part Number: 5521-B-400.
Howmedica Osteonics
Stryker has identified that Triathlon Universal Baseplate Size 3 (lot UZD9IB), is contained in packaging labeled as Triathlon Universal Baseplate Size 4 (lot TYX7OB), and Triathlon Universal Baseplate Size 4 (lot TYX7OB), is contained in packaging labeled as Triathlon Universal Baseplate Size 3, (lot UZD9IB).
MICS3 Angled Sagittal Saw Attachment; Part Number: 210490
Howmedica Osteonics
A potential issue was identified with the torque strength on the external screws of the MICS3 Angled Sagittal Saw Attachment. These screws, which secure the cover to the Angled Saw Housing, may loosen during use and detach from the attachment.