AmniSure ROM Test under the following labels: 1) Catalog Number FMRT-1-25 and 2) Catalog Number FMRT-1-25-CA Product Usage: Rapid, non-instrumented, qualitative immunochromatographic test for the in vitro detection of amniotic fluid in vaginal discharge of pregnant women.
Class I - DangerousWhat Should You Do?
- Check if you have this product: 1) UDI 14053228022319; Lot Numbers - 557016546, 557016547 & 5600115, Exp Date 7/28/2020 2) UDI 14053228022333; Lot Number - 557016409, Exp Date 7/28/2020
- Do not eat it: Even if it looks and smells fine, do not consume this product.
- Throw it away or return it: You can return the product to the store for a full refund.
- Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
- Report problems: Report any issues to the FDA's Safety Reporting Portal.
⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.
Recall Details
- Company:
- Qiagen Sciences, Inc.
- Reason for Recall:
- Potential for control line not appearing on the test strip
- Classification:
- Class I - Dangerous
Dangerous or defective products that predictably could cause serious health problems or death.
- Status:
- terminated
Product Information
Full Description:
AmniSure ROM Test under the following labels: 1) Catalog Number FMRT-1-25 and 2) Catalog Number FMRT-1-25-CA Product Usage: Rapid, non-instrumented, qualitative immunochromatographic test for the in vitro detection of amniotic fluid in vaginal discharge of pregnant women.
Product Codes/Lot Numbers:
1) UDI 14053228022319; Lot Numbers - 557016546, 557016547 & 5600115, Exp Date 7/28/2020 2) UDI 14053228022333; Lot Number - 557016409, Exp Date 7/28/2020
Official Source
Always verify recall information with the official FDA source:
View on FDA.govFDA Recall Number: Z-2577-2018
Related Recalls
Brand Name: QIAstat-Dx Product Name: QIAstat-Dx Respiratory Panel Plus Reference Number (REF): 691224 Software Version: n/a Component: n/a
Qiagen Sciences
Identified faulty cartridges. If such a faulty cartridge is used for sample testing, false test results could occur.
Heater shaker module does not perform heating if the temperature is set below 40¿C for static incubation steps when running IVD protocol QIAamp¿ DSP DNA Mini Kit (cat. no. 61304), Protocol: Isolation of genomic DNA from Gram-positive bacteria (Script filename: Kt_name_Bacteria (Gram+) or rY'east_Enzymatic Lysis_ V2) which could potentially cause delayed or erroneous results depending on the downstream assay.
Insufficient welding leads to the heater cable becoming brittle and present with an error: ERROR 3481 HEATER UNABLE TO REACH TEMPERATURE; the instrument may stop, and the sample being processed will be lost