BD Alaris PCEA Administration Set, Microbore Tubing with Yellow Identification Stripe ASV, Catalog Number 10800177 - Product Usage: Microbore Tubing with Yellow Identification Stripe Anti-siphon Valve Use Aseptic Technique Set cannot be used for gravity infusion. 1. Connect PCA syringe to female luer on administration set. 2. Push on syringe plunger to prime set. 3. Refer to PCA module Directions for Use for complete loading and operating instructions. Notes: The set should be changed according to facility protocol or in accordance with currently recognized guidelines for IV therapy. Antisiphon sets cannot be primed by gravity.

Class I - Dangerous

What Should You Do?

  1. Check if you have this product:
    UDI: 10885403234422; Lot Numbers: 19016200 19045273
  2. Do not eat it: Even if it looks and smells fine, do not consume this product.
  3. Throw it away or return it: You can return the product to the store for a full refund.
  4. Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
  5. Report problems: Report any issues to the FDA's Safety Reporting Portal.

โš ๏ธ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.

Recall Details

Company:
BD SWITZERLAND SARL
Reason for Recall:
The products have the potential to leak between the connection of the male luer and the yellow striped tubing. This leak may be observed while priming or during use. The most likely health consequence associated with a leak in an administration set would be inadequate pain control for the patient due to an under-infusion of medication.
Classification:
Class I - Dangerous

Dangerous or defective products that predictably could cause serious health problems or death.

Status:
terminated

Product Information

Full Description:

BD Alaris PCEA Administration Set, Microbore Tubing with Yellow Identification Stripe ASV, Catalog Number 10800177 - Product Usage: Microbore Tubing with Yellow Identification Stripe Anti-siphon Valve Use Aseptic Technique Set cannot be used for gravity infusion. 1. Connect PCA syringe to female luer on administration set. 2. Push on syringe plunger to prime set. 3. Refer to PCA module Directions for Use for complete loading and operating instructions. Notes: The set should be changed according to facility protocol or in accordance with currently recognized guidelines for IV therapy. Antisiphon sets cannot be primed by gravity.

Product Codes/Lot Numbers:

UDI: 10885403234422; Lot Numbers: 19016200 19045273

Official Source

Always verify recall information with the official FDA source:

View on FDA.gov

FDA Recall Number: Z-1968-2020

Related Recalls

BD PhaSeal Injector Luer (N30C), REF: 515001 BD PhaSeal Injector Luer Lock (N35), REF: 515003 BD PhaSeal Injector Luer Lock (N35C), REF: 515004 BD PhaSeal Injector Lu63er Lock (N35C Multi), REF: 515005 BD PhaSeal Protector (P14), REF: 515100 BD PhaSeal Protector (P21), REF: 515102 BD PhaSeal Protector (P21 Multi), REF: 515103 BD PhaSeal Protector (P28), REF: 515104 BD PhaSeal Protector (P50), REF: 515105 BD PhaSeal Protector (P50 Multi), REF: 515106 BD PhaSeal Protector (P53), REF: 515107 BD PhaSeal Protector (P55), REF: 515117 BD PhaSeal Connector Luer Lock (C35), REF: 515200 BD PhaSeal Connector Luer Lock (C45), REF: 515202 BD PhaSeal Y-site Connector (C80), REF: 515304 BD PhaSeal L Connector (C90), REF: 515305 BD PhaSeal Infusion Adapter (C100), REF: 515306 BD PhaSeal Infusion Adapter (C100 Multi), REF: 515307 BD PhaSeal Cap for Injector (M50), REF: 515404 BD PhaSeal Connector Cap (M70), REF: 515406 BD PhaSeal Optima Injector (N35-O), REF: 515052 BD PhaSeal Optima Injector (N35-O Multi), REF: 515053 BD PhaSeal Injector Locking (N40-O), REF: 515056 BD PhaSeal Injector Locking (N40-O Multi), REF: 515057 BD PhaSeal Optima Protector (P13-O), REF: 515060 BD PhaSeal Optima Protector (P13-O Multi), REF: 515062 BD PhaSeal Optima Protector (P28-O), REF: 515063 BD PhaSeal Optima Protector (P20-O), REF: 515064 BD PhaSeal Optima Protector (P20-O Multi), REF: 515065 BD PhaSeal Optima Connector (C35-O), REF: 515070 BD PhaSeal Optima Infusion Adapter (C100-O), 515078 BD PhaSeal Optima Infusion Adapter (C100-O Multi), REF: 515079

BD SWITZERLAND SARL

Class I - Dangerous

Closed system drug transfer devices were shipped to the U.S. market without a U.S. version of the instructions for use, which could be an issue if a healthcare professional is prompted to review it.

Jun 16, 2025 Infusion Pumps Nationwide View Details โ†’

Sterile, single use closed system drug transfer devices, standalone or on infusion sets or bonded syringes, may leak at the interface between the closed male luer component and the needle-free connector, which may cause procedure delay, treatment interruptions, exposure to hazardous drugs, and/or underdosing of medication.

May 12, 2025 Other Medical Devices Nationwide View Details โ†’

Sterile, single use closed system drug transfer devices, standalone or on infusion sets or bonded syringes, may leak at the interface between the closed male luer component and the needle-free connector, which may cause procedure delay, treatment interruptions, exposure to hazardous drugs, and/or underdosing of medication.

May 12, 2025 Surgical Instruments Nationwide View Details โ†’