Bag size #4 Custom Convenience Kits Usage: Surgical convenience kits labeled as the following: a. Tray Name: PACK BASIC SET UP LH - 2035102, Tray Number: LSRBASICPACD; b. Tray Name: PACK ANGIOGRAM CFH - 2071297, Tray Number: LSRCFHANGD; c. Tray Name: PACK BASIC VIII CFH - 2073903, Tray Number: LSRCFBVIIIPKE; d. Tray Name: PACK BASIC VIII CFH -2072667, Tray Number: LSRCFBVIIIPKD; e. Tray Name: PACK BREAST GARRAMONE, Tray Number: LSRGABRSB; f. Tray Name: PACK CARDIAC CATH LH - 2073653, Tray Numbers: LSRCARDCATHF, LSRCFHCATHE; g. Tray Name: PACK CAROTID CFH - 2022261, Tray Number: LSRCFHCARC; h. Tray Name: PACK CAROTID CFH - 2070082, Tray Number: LSRCFHCARD; i. Tray Name: PACK CATH PACK CFH - 2065429, Tray Number: LSRCFHCATHD; j. Tray Name: PACK CYSTO-TUR CFH - 2066423, Tray Number: LSRCFHCYTURC; k. Tray Name: PACK D-C GYN CFH - 2023208, Tray Number: LSRCFHDCGYNC; l. Tray Name: PACK D-C LH - 2067690, Tray Number: LSRLMDCA; m. Tray Name: PACK EENT CFH - 2023005, Tray Number: LSRCFENTB; n. Tray Name: PACK EENT CFH - 2073904, Tray Number: LSRCFENTC; o. Tray Name: PACK ENDOSCOPIC LH - 2073429, Tray Numbers: LSRENDOSCOPG, LSRENDOSCOPH; p. Tray Name: PACK ENDOVENOUS LH - 2072299, Tray Number: LSRLMENDOVB; q. Tray Name: PACK GENERIC A - 2018972, Tray Number: LSRMISCA; r. Tray Name: PACK HP GYN LAPAROSCOPY LH -2067955, Tray Number: LSRHPGYND; s. Tray Name: PACK KNEE ARTHROSCOPY SMHS - 2065237, Tray Number: LSRKNEEARTHF; t. Tray Name: PACK OCCULAR DRAPE LH - 2034766, Tray Number: LSROCCULARC; u. Tray Name: PACK OPHTHALMOLOGY LH - 2034932, Tray Number: LSROPHTHALD; v. Tray Name: PACK PICC LINE LH - 2008070, Tray Number: LSRPICCLINEG; w. Tray Name: PACK SHOULDER SMHS - 2065241, Tray Number: LSRSHOULDERD; x. Tray Name: PACK SINGLE BASIN LH - 2064837, Tray Number: LSRSINGLEBA; y. Tray Name: PACK STOCK PACEMAKER CFH - 2069578, Tray Number: LSRCFHPACRE; z. Tray Name: PACK VAGINAL DELIVERY SMHS - 2068301, Tray Number: LSRVAGDELIVC; aa. Tray Name: PACK CYSTO DECATUR - 2047265, Tray Number: LSRDECYSTA; bb. Tray Name: PACK MINOR DECATUR - 2071628, Tray Number: LSRDEMINB
Class I - DangerousWhat Should You Do?
- Check if you have this product: Tray Number (Lot Number): a. Tray Number: LSRBASICPACD (1610281, 1611301, 1701041, 1701301, 1702111, 1702201, 1703171, 1703232, 1704101, 1705052, 1705061, 1705092, 1705252, 1706141, 1707101, 1708041, 1708291, 1710132); b. Tray Number: LSRCFHANGD (1611091, 1701052, 1702232, 1703141, 1705082, 1705101, 1707071, 1708301); c. Tray Number: LSRCFBVIIIPKE (1709071/2); d. Tray Number: LSRCFBVIIIPKD (1612021, 1701251, 1703142, 1704111, 1705241, 1707171, 1708071); e. Tray Number: LSRGABRSB (1701112, 1703101, 1704271, 1706082, 1708112); f. Tray Numbers: LSRCARDCATHF (1706271, 1707131, 1707241, 1708141, 1708311, 1710011, 1710031), LSRCFHCATHE (1610291, 1611281, 1612282, 1701231, 1702041, 1702071, 1703071, 1703202, 1703271, 1703301, 1704141, 1704192,1704282, 1705091, 1705182, 1705232, 1705312, 1706121); g. Tray Number: LSRCFHCARC (1611111, 1701101, 1702272, 1705012, 1706201, 1707221); h. Tray Number: LSRCFHCARD (1709061, 1710241); i. Tray Number: LSRCFHCATHD (1610312, 1611181, 1612301, 1701231, 1702032, 1702041, 1702081, 1702231, 1703162, 1704121, 1704261, 1705051, 1705161, 1705241, 1706082, 1706211, 1707101, 1707261, 1708151, 1709011, 1710052, 1710261); j. Tray Number: LSRCFHCYTURC (1611181, 1702062, 1702141, 1703151, 1704262, 1705171, 1706261, 1707171, 1708142, 1709052, 1710271); k. Tray Number: LSRCFHDCGYNC (1611032, 1701281, 1703221, 1705012, 1706081, 1707221, 1709292); l. Tray Number: LSRLMDCA (1611071, 1702081, 1704192, 1707241, 1710091); m. Tray Number: LSRCFENTB (1611031, 1612162, 1701231, 1703081, 1704291, 1706121, 1707201); n. Tray Number: LSRCFENTC (1708231); o. Tray Numbers: LSRENDOSCOPG (1611041, 1701041, 1702151), LSRENDOSCOPH (1703301, 1705051/2, 1706061, 1707032, 1708011, 1709061, 1710271); p. Tray Number: LSRLMENDOVB (1611021, 1703062, 1703292, 1704271, 1705091, 1708251); q. Tray Number: LSRMISCA (1702181); r. Tray Number: LSRHPGYND (1611071, 1612211, 1702092, 1704061, 1705102, 1706161, 1707201, 1709191); s. Tray Number: LSRKNEEARTHF (1611291, 1612241, 1702141, 1703081, 1704182, 1705171, 1707062, 1708182); t. Tray Number: LSROCCULARC (1611171, 1703152, 1705052, 1708042); u. Tray Number: LSROPHTHALD (1611021, 1701301, 1703292, 1707141); v. Tray Number: LSRPICCLINEG (1612212, 1702061, 1703151, 1704291, 1706131, 1707181, 1708311); w. Tray Number: LSRSHOULDERD (1611302, 1701131, 1702092, 1703082, 1704061, 1706031, 1708182); x. Tray Number: LSRSINGLEBA (1610261, 1611151, 1611221, 1612091, 1612232, 1701101, 1701172, 1701312, 1702022, 1702092, 1702111, 1702181, 1702231, 1703181, 1704011, 1704112, 1704191, 1704282, 1705011, 1705081, 1705181/2,1705221, 1705311,1706121, 1706141, 1706201, 1707071, 1707121, 1707171, 1707221, 1707271, 1708071, 1708101, 1708112, 1708141, 1708241, 1708312, 1709071, 1709201, 1710021, 1710122, 1710241); y. Tray Number: LSRCFHPACRE (1612191, 1702061, 1704251, 1704261, 1706151, 1707142, 1708181, 1710102); z. Tray Number: LSRVAGDELIVC (1612021, 1701251, 1703161, 1704242, 1706061, 1707032, 1708021, 1708172, 1709201); aa. Tray Number: LSRDECYSTA (1611091, 1611141, 1612211, 1702062, 1702141, 1703012, 1704182, 1705032, 1705171, 1709061, 1710181); bb. Tray Number: LSRDEMINB (1611111, 1612051, 1701311, 1703301, 1706011, 1706052, 1707071, 1707261, 1708171, 1709291)
- Do not eat it: Even if it looks and smells fine, do not consume this product.
- Throw it away or return it: You can return the product to the store for a full refund.
- Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
- Report problems: Report any issues to the FDA's Safety Reporting Portal.
⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.
Recall Details
- Company:
- American Contract Systems, Inc.
- Reason for Recall:
- Potential that product has not reached complete sterilization,
- Classification:
- Class I - Dangerous
Dangerous or defective products that predictably could cause serious health problems or death.
- Status:
- terminated
Product Information
Full Description:
Bag size #4 Custom Convenience Kits Usage: Surgical convenience kits labeled as the following: a. Tray Name: PACK BASIC SET UP LH - 2035102, Tray Number: LSRBASICPACD; b. Tray Name: PACK ANGIOGRAM CFH - 2071297, Tray Number: LSRCFHANGD; c. Tray Name: PACK BASIC VIII CFH - 2073903, Tray Number: LSRCFBVIIIPKE; d. Tray Name: PACK BASIC VIII CFH -2072667, Tray Number: LSRCFBVIIIPKD; e. Tray Name: PACK BREAST GARRAMONE, Tray Number: LSRGABRSB; f. Tray Name: PACK CARDIAC CATH LH - 2073653, Tray Numbers: LSRCARDCATHF, LSRCFHCATHE; g. Tray Name: PACK CAROTID CFH - 2022261, Tray Number: LSRCFHCARC; h. Tray Name: PACK CAROTID CFH - 2070082, Tray Number: LSRCFHCARD; i. Tray Name: PACK CATH PACK CFH - 2065429, Tray Number: LSRCFHCATHD; j. Tray Name: PACK CYSTO-TUR CFH - 2066423, Tray Number: LSRCFHCYTURC; k. Tray Name: PACK D-C GYN CFH - 2023208, Tray Number: LSRCFHDCGYNC; l. Tray Name: PACK D-C LH - 2067690, Tray Number: LSRLMDCA; m. Tray Name: PACK EENT CFH - 2023005, Tray Number: LSRCFENTB; n. Tray Name: PACK EENT CFH - 2073904, Tray Number: LSRCFENTC; o. Tray Name: PACK ENDOSCOPIC LH - 2073429, Tray Numbers: LSRENDOSCOPG, LSRENDOSCOPH; p. Tray Name: PACK ENDOVENOUS LH - 2072299, Tray Number: LSRLMENDOVB; q. Tray Name: PACK GENERIC A - 2018972, Tray Number: LSRMISCA; r. Tray Name: PACK HP GYN LAPAROSCOPY LH -2067955, Tray Number: LSRHPGYND; s. Tray Name: PACK KNEE ARTHROSCOPY SMHS - 2065237, Tray Number: LSRKNEEARTHF; t. Tray Name: PACK OCCULAR DRAPE LH - 2034766, Tray Number: LSROCCULARC; u. Tray Name: PACK OPHTHALMOLOGY LH - 2034932, Tray Number: LSROPHTHALD; v. Tray Name: PACK PICC LINE LH - 2008070, Tray Number: LSRPICCLINEG; w. Tray Name: PACK SHOULDER SMHS - 2065241, Tray Number: LSRSHOULDERD; x. Tray Name: PACK SINGLE BASIN LH - 2064837, Tray Number: LSRSINGLEBA; y. Tray Name: PACK STOCK PACEMAKER CFH - 2069578, Tray Number: LSRCFHPACRE; z. Tray Name: PACK VAGINAL DELIVERY SMHS - 2068301, Tray Number: LSRVAGDELIVC; aa. Tray Name: PACK CYSTO DECATUR - 2047265, Tray Number: LSRDECYSTA; bb. Tray Name: PACK MINOR DECATUR - 2071628, Tray Number: LSRDEMINB
Product Codes/Lot Numbers:
Tray Number (Lot Number): a. Tray Number: LSRBASICPACD (1610281, 1611301, 1701041, 1701301, 1702111, 1702201, 1703171, 1703232, 1704101, 1705052, 1705061, 1705092, 1705252, 1706141, 1707101, 1708041, 1708291, 1710132); b. Tray Number: LSRCFHANGD (1611091, 1701052, 1702232, 1703141, 1705082, 1705101, 1707071, 1708301); c. Tray Number: LSRCFBVIIIPKE (1709071/2); d. Tray Number: LSRCFBVIIIPKD (1612021, 1701251, 1703142, 1704111, 1705241, 1707171, 1708071); e. Tray Number: LSRGABRSB (1701112, 1703101, 1704271, 1706082, 1708112); f. Tray Numbers: LSRCARDCATHF (1706271, 1707131, 1707241, 1708141, 1708311, 1710011, 1710031), LSRCFHCATHE (1610291, 1611281, 1612282, 1701231, 1702041, 1702071, 1703071, 1703202, 1703271, 1703301, 1704141, 1704192,1704282, 1705091, 1705182, 1705232, 1705312, 1706121); g. Tray Number: LSRCFHCARC (1611111, 1701101, 1702272, 1705012, 1706201, 1707221); h. Tray Number: LSRCFHCARD (1709061, 1710241); i. Tray Number: LSRCFHCATHD (1610312, 1611181, 1612301, 1701231, 1702032, 1702041, 1702081, 1702231, 1703162, 1704121, 1704261, 1705051, 1705161, 1705241, 1706082, 1706211, 1707101, 1707261, 1708151, 1709011, 1710052, 1710261); j. Tray Number: LSRCFHCYTURC (1611181, 1702062, 1702141, 1703151, 1704262, 1705171, 1706261, 1707171, 1708142, 1709052, 1710271); k. Tray Number: LSRCFHDCGYNC (1611032, 1701281, 1703221, 1705012, 1706081, 1707221, 1709292); l. Tray Number: LSRLMDCA (1611071, 1702081, 1704192, 1707241, 1710091); m. Tray Number: LSRCFENTB (1611031, 1612162, 1701231, 1703081, 1704291, 1706121, 1707201); n. Tray Number: LSRCFENTC (1708231); o. Tray Numbers: LSRENDOSCOPG (1611041, 1701041, 1702151), LSRENDOSCOPH (1703301, 1705051/2, 1706061, 1707032, 1708011, 1709061, 1710271); p. Tray Number: LSRLMENDOVB (1611021, 1703062, 1703292, 1704271, 1705091, 1708251); q. Tray Number: LSRMISCA (1702181); r. Tray Number: LSRHPGYND (1611071, 1612211, 1702092, 1704061, 1705102, 1706161, 1707201, 1709191); s. Tray Number: LSRKNEEARTHF (1611291, 1612241, 1702141, 1703081, 1704182, 1705171, 1707062, 1708182); t. Tray Number: LSROCCULARC (1611171, 1703152, 1705052, 1708042); u. Tray Number: LSROPHTHALD (1611021, 1701301, 1703292, 1707141); v. Tray Number: LSRPICCLINEG (1612212, 1702061, 1703151, 1704291, 1706131, 1707181, 1708311); w. Tray Number: LSRSHOULDERD (1611302, 1701131, 1702092, 1703082, 1704061, 1706031, 1708182); x. Tray Number: LSRSINGLEBA (1610261, 1611151, 1611221, 1612091, 1612232, 1701101, 1701172, 1701312, 1702022, 1702092, 1702111, 1702181, 1702231, 1703181, 1704011, 1704112, 1704191, 1704282, 1705011, 1705081, 1705181/2,1705221, 1705311,1706121, 1706141, 1706201, 1707071, 1707121, 1707171, 1707221, 1707271, 1708071, 1708101, 1708112, 1708141, 1708241, 1708312, 1709071, 1709201, 1710021, 1710122, 1710241); y. Tray Number: LSRCFHPACRE (1612191, 1702061, 1704251, 1704261, 1706151, 1707142, 1708181, 1710102); z. Tray Number: LSRVAGDELIVC (1612021, 1701251, 1703161, 1704242, 1706061, 1707032, 1708021, 1708172, 1709201); aa. Tray Number: LSRDECYSTA (1611091, 1611141, 1612211, 1702062, 1702141, 1703012, 1704182, 1705032, 1705171, 1709061, 1710181); bb. Tray Number: LSRDEMINB (1611111, 1612051, 1701311, 1703301, 1706011, 1706052, 1707071, 1707261, 1708171, 1709291)
Distribution:
Distributed in: US
Official Source
Always verify recall information with the official FDA source:
View on FDA.govFDA Recall Number: Z-0964-2019
Related Recalls
Convenience kits containing Medline Namic Angiographic Control Syringes with Rotating Adaptor CORONARY ANGIO PACK Model numbers ANCA80AP ANCA80AQ
American Contract Systems
Impacted kits contain syringes recalled by Medline Industries. Syringe rotating adaptor may unwind during use, which may result in a loose connection or full disconnection between the syringe and manifold. Potential risk for biohazard exposure, blood loss, infection, or air embolism.
Medical convenience kits Item Number/Description HSAN63N ANGIO PACK IHAN02W ANGIOGRAPHY PACK MHCA98AK CORONARY ANGIO PACK- 205991 RCAN45C ANGIO CUSTOM RCH UDCO10F CVL CORONARY PACK 219224
American Contract Systems
Identified products were re-gassed (sterilized more than once) after a nonconformance occurred during the initial Ethylene Oxide (EO) gas injection process. These products have not been validated for exposure to multiple sterilization cycles. Therefore, product quality, safety, and effectiveness cannot be confirmed for product that was re-gassed.
Identified products were re-gassed (sterilized more than once) after a nonconformance occurred during the initial Ethylene Oxide (EO) gas injection process. These products have not been validated for exposure to multiple sterilization cycles. Therefore, product quality, safety, and effectiveness cannot be confirmed for product that was re-gassed.